MEDTRONIC DEVICE FEATURES

Welcome to the NEW Medtronic Device Features website on Medtronic Academy!

Find information on Medtronic cardiac device features, including programming information, feature operation, examples, and performance data.  Browse the site by features or device type.

To access the Device Features content below, you will need to LOGIN or REGISTER on Medtronic Academy.

 

NEW Device Features webclip app for iPhone/iPad

Click here from your iPhone/iPad Safari browser to place the new app on your iPhone/iPad home screen for ease of access to Device Features. If you  are currently using the legacy Device Features app, please replace with the new app for best results.

 

 

PACEMAKER (IPG)


Atrial Capture Management (ACM)

Atrial Preference Pacing (APP)

Atrial Rate Stabilization (ARS)

Automatic PVARP

Cardiac Compass Trends

Conducted AF Response (CAFR)

Implant Detection

Lead Monitor

MRI SureScan

Magnet

Managed Ventricular Pacing (MVP)

Mode Switch

Non-Competitive Atrial Pacing (NCAP)

PMT Intervention

PVC Response

Post Mode-Switch Overdrive Pacing (PMOP)

Rate Adaptive AV (RAAV)

Rate Drop Response (RDR)

Rate Histograms

Rate Response (RR)

Reactive ATP

Search AV+

Sensing Assurance

Single Chamber/Rate Hysteresis

Sinus Preference

Sleep Function

TherapyGuide

Ventricular Capture Management (VCM)

Ventricular Rate Stabilization (VRS)

Ventricular Safety Pacing (VSP)


 

IMPLANTABLE CARDIOVERTER DEFIBRILLATOR (ICD)


AF Detection

ATP Before/During Charging Feature

Active Can/SVC Coil Feature

Atrial Capture Management (ACM)

Atrial Preference Pacing (APP)

Atrial Rate Stabilization (ARS)

Automatic PVARP

Cardiac Compass Trends

ChargeSaver/Switchback

Conducted AF Response (CAFR)

Confirmation+

High Rate Timeout

Left Ventricular Capture Management Feature (LVCM)

MRI SureScan

Magnet

Managed Ventricular Pacing (MVP)

Mode Switch

Non-Competitive Atrial Pacing (NCAP)

Onset

OptiVol Fluid Status Trend

PMT Intervention

PR Logic

PVC Response

Post Mode-Switch Overdrive Pacing (PMOP)

Progressive Episode Detection

RV Lead Integrity Alert (LIA)

RV Lead Noise Discrimination

RV Sense Polarity

Rate Adaptive AV (RAAV)

Rate Drop Response (RDR)

Rate Histograms

Rate Response (RR)

Reactive ATP

Single Chamber/Rate Hysteresis

Sleep Function

Stability

TWave Discrimination

TherapyGuide

Ventricular Anti-Tachycardia Pacing

Ventricular Capture Management (VCM)

Ventricular Rate Stabilization (VRS)

Ventricular Safety Pacing (VSP)

Wavelet


 

CARDIAC RESYNCHRONIZATION THERAPY (CRT)


ATP Before/During Charging

Active Can/SVC Coil

AdaptivCRT

Atrial Capture Management (ACM)

Atrial Preference Pacing (APP)

Atrial Rate Stabilization (ARS)

Atrial Tracking Recovery (ATR)

Automatic PVARP

Cardiac Compass Trends

CardioSync Optimization

ChargeSaver/Switchback

Conducted AF Response (CAFR)

Confirmation+

High Rate Timeout

Implant Detection

Lead Monitor

Left Ventricular Capture Management

MRI SureScan

Magnet

Managed Ventricular Pacing (MVP)

Mode Switch

Non-Competitive Atrial Pacing (NCAP)

Onset

OptiVol Fluid Status Trend

PMT Intervention

PR Logic

PVC Response

Post Mode-Switch Overdrive Pacing (PMOP)

Progressive Episode Detection

RV Lead Integrity Alert (LIA)

RV Lead Noise Discrimination

RV Sense Polarity

Rate Adaptive AV (RAAV)

Rate Drop Response (RDR)

Rate Histograms

Rate Response (RR)

Reactive ATP

Sleep Function

Stability

TWave Discrimination

TherapyGuide

VectorExpress LV Automated Test

Ventricular Anti-Tachycardia Pacing

Ventricular Capture Management (VCM)

Ventricular Rate Stabilization (VRS)

Ventricular Safety Pacing (VSP)

Ventricular Sense Response (VSR)

Wavelet


 

INSERTABLE CARDIAC MONITOR (ICM)


AT/AF Episode Detection

Brady Episode Detection

Cardiac Compass Trends

Pause Episode Detection

Rate Histograms

Tachy Episode Detection

 

 

Medtronic offers many valuable device features to help you manage your patient.

Features Found in Pacemaker, ICD and CRT Device

  • Capture Management (ACM, VCM, LVCM) automatically monitors pacing thresholds in the appropriate chamber at periodic intervals.  Once the threshold is determined, target outputs are determined based on the programmable safety margins and minimum amplitudes.
  • Managed Ventricular Pacing (MVP) is a pacing mode promotes intrinsic conduction by reducing unnecessary right ventricular pacing, but with the safety of backup dual chamber pacing if intrinsic conduction is lost.
  • MRI SureScan permits a mode of operation that allows a patient with a SureScan pacing system to be safely scanned by an MRI machine while the device continues to provide the appropriate programmed therapy. 
  • Reactive ATP allows for multiple deliveries of programmed atrial ATP therapies during an atrial tachyarrhythmia. 

Features Found in ICD and CRT Devices

  • OptiVol™ Fluid Status Trend that track intrathoracic impedance changes over time for up to 14 months.
  • SmartShock™ Technology dramatically reduces the incidence of inappropriate shocks while maintaining sensitivity1,2                          
    • PR Logic uses pattern and rate analysis to discriminate between supraventricular tachycardia and true ventricular tachyarrhythmia.
    • Wavelet is a QRS morphology discriminator that compares the current QRS waveform to a stored QRS template, collected during sinus rhythm.
    • TWave Discrimination designed to withhold therapy if there is evidence that a fast ventricular rate is due to T wave oversensing.
    • RV Lead Noise Discrimination differentiates RV lead noise from VT/VF by comparing a far field EGM signal to the near field sensing if lead noise is suspected.
    • RV Lead Integrity Alert (LIA) provides advance warning for lead fracture and extends the VF detection time when a lead fracture is detected in order to reduce the risk of multiple inappropriate shocks.
    • Confirmation+ compares the rhythm cycle length to a calculated confirmation interval to confirm the presence of an arrhythmia.

Features Found in CRT Devices

  • AdaptivCRT™ is a dynamic, physiologic pacing algorithm that enhances cardiac resynchronization therapy (CRT) by adjusting CRT parameters automatically with changes in patient activity levels and conduction status.  It leverages a patient’s intrinsic RV conduction when possible while still maintaining CRT.
  • VectorExpress™ LV Automated Test is an in-office programmer based algorithm that allows automated testing of clinician-selected LV pacing polarities.

References

  1. Volosin, KJ, Exner DV, Wathen MS, et al. Combining shock reduction strategies to enhance ICD therapy: A role for computer modeling. J Cardiovasc Electrophysiol. March 2011;22(3):280-289.
  2. Schloss EJ, Auriccho A, Kurtia T, et al. PainFree SST Trial Primary Results: Low shock rates in patients with dual and triple Chamber ICDs using a novel detection algorithms. Heart Rhythm. 2013;10 (5):S64.
Last updated: 
31 Mar 2016

Reference Information

Please access the Indications, Safety, and Warnings or Medtronic's Technical Manuals to learn more about Medtronic products and labeling.